Free tool · Home and DIY
AC ton calculator
Type the size of your room, how sunny it is and how many people use it. You get the cooling you need in BTU per hour and in tons.
- Free
- No sign-up
- Runs in your browser
9,000 BTU/h0.75 ton of cooling
- 0.75 ton
- 400 sq ft room
- 2 people
- Chart size for the room
- 9,000 BTU/h
- Sun adjustment
- none
- Extra people
- none
- Kitchen
- none
Your working: a room of 400 sq ft falls in the 350 to 400 sq ft band, which the chart gives as 9,000 BTU/h. Then none for sun, none for people and none for a kitchen make 9,000 BTU/h. 9,000 ÷ 12,000 = 0.750 ton.
The chart assumes an 8-foot ceiling. Pick a real unit close to this size, since units come in set capacities.
How to use the AC Ton Calculator
- Type the Room area and choose square feet or square meters.
- Pick how much sun the room gets under How much sun does the room get?
- Type how many People who are usually in the room, and tick the box if it is a kitchen.
- Read the BTU per hour and the tons in the big answer, and the steps under it.
How many tons of air conditioning do I need?
Find your room size on the chart, take the BTU per hour next to it, then divide by 12,000 to get tons. A 400 square foot room with normal sun and two people sits in the 350 to 400 band, which the chart gives as 9,000 BTU/h. That is 9,000 ÷ 12,000 = 0.75 ton.
One ton of cooling is 12,000 BTU per hour. The word "ton" comes from the old days of cooling with ice, and today it is only a name for that amount of cooling. It has nothing to do with how much the unit weighs.
What is the sizing chart?
The chart below is the sizing chart on the ENERGY STAR page for room air conditioners. It gives the cooling in BTU per hour for a room area, and it assumes an 8-foot ceiling. Where a room lands on the edge of two bands, this page uses the lower band, so a room of exactly 400 square feet is read as 350 to 400.
The chart covers rooms from 100 to 2,500 square feet. Smaller or larger spaces are outside it, and the page says so instead of guessing.
| Area (sq ft) | BTU per hour | Tons |
|---|---|---|
| 100 to 150 | 5,000 | 0.42 |
| 150 to 250 | 6,000 | 0.50 |
| 250 to 300 | 7,000 | 0.58 |
| 300 to 350 | 8,000 | 0.67 |
| 350 to 400 | 9,000 | 0.75 |
| 400 to 450 | 10,000 | 0.83 |
| 450 to 550 | 12,000 | 1.00 |
| 550 to 700 | 14,000 | 1.17 |
| 700 to 1,000 | 18,000 | 1.50 |
| 1,000 to 1,200 | 21,000 | 1.75 |
| 1,200 to 1,400 | 23,000 | 1.92 |
| 1,400 to 1,500 | 24,000 | 2.00 |
| 1,500 to 2,000 | 30,000 | 2.50 |
| 2,000 to 2,500 | 34,000 | 2.83 |
What changes the size I need?
The same page lists four adjustments, and this calculator applies them for you. A heavily shaded room needs 10% less, and a very sunny room 10% more. With strong sun, the 400 square foot room grows from 9,000 to 9,900 BTU/h. Each regular occupant beyond two adds 600 BTU/h, so six people in that room add 2,400 and make 11,400 BTU/h in all. A kitchen adds 4,000 BTU/h.
The kitchen rule moves a 300 square foot room from 7,000 to 11,000 BTU/h, which is 0.92 ton. The percent changes are applied to the chart figure first, and the fixed amounts are added afterwards.
Can I enter the room in square meters?
Yes. Choose square meters and the page converts to square feet, with 1 square meter equal to 10.76 square feet. A room of 30 square meters is 323 square feet, which gives 8,000 BTU/h or 0.67 ton.
To find the area, multiply the length by the width. For an L-shaped room, split it into two rectangles and add them.
How do I read the result?
The big figure is the cooling you should shop for, in BTU per hour. The facts under it show where it came from: the chart size, then each adjustment on its own line. For the 400 square foot example the chart size is 9,000 BTU/h and no adjustment applies, so the total is the same 9,000. Change one answer at a time to see how much each one moves the total.
Sellers list room air conditioners in BTU per hour, and larger central systems are often sold in tons. If you need to compare, remember that 12,000 BTU per hour is one ton, so a 9,000 BTU/h unit is three quarters of a ton.
The chart is a starting point for a single room. It does not know about your climate, your windows or how well the room is sealed, so a result close to a unit size could go either way. When in doubt, ask the seller or an installer to check the figure against the room.
Should I pick a bigger unit to be safe?
A unit that is too big cools the room quickly and then switches off before it has had time to take the damp out of the air, so the room can feel clammy. Pick a unit close to the size shown. Units come in set capacities, so take the nearest one that is not far below your figure.
This calculator suits a single room with an 8-foot ceiling. Rooms with higher ceilings, large windows or poor insulation are a job for an installer, who can look at the space itself.
Use it with
- Watts to Amps Converter: current drawn by a load at a given voltage, DC or AC.
- Electricity Cost Calculator: cost to run any appliance.
- kVA to Amps Converter: current of single or three phase loads from kVA.
Questions
How many BTU per square foot do I need?
It is not a fixed rate. The chart gives 10,000 BTU/h for 400 to 450 sq ft and 5,000 for 100 to 150 sq ft. Use the tool so the band and the adjustments are applied.
How many BTU is 1 ton of AC?
One ton is 12,000 BTU per hour. So 18,000 BTU/h is 1.5 tons and 24,000 BTU/h is 2 tons.
What size AC do I need for a 400 sq ft room?
With normal sun and two people, the chart gives 9,000 BTU/h, or 0.75 ton. Very sunny adds 10%, which is 9,900 BTU/h.
Does ceiling height matter?
Yes. The chart assumes an 8-foot ceiling, so a taller room needs more. This page does not adjust for it.
What if I have more than two people?
Add 600 BTU/h for each regular occupant beyond two. Six people in a 400 sq ft room make 11,400 BTU/h.
Is a bigger AC always better?
No. An oversized unit can switch off too soon and leave the room damp. Aim for the size shown.
The tool's results are computed in your browser by the code on this page, using the sources listed above; the explanations are checked against the tool's own output.