Worked answer · All-in-One Unit Converter
Tons of Refrigeration to Kilowatts
1 ton of refrigeration is 3.516852842 kW, and 1 kilowatt is 0.2843451361 TR. Type any value in the converter.
- 1 TR = 3.516852842 kW
- Exact factor
263.7639632 kW75 TR converted to Kilowatt (kW)
- 1 TR = 3.516852842 kW
- 1 kW = 0.2843451361 TR
- Exact factors
- Multiply by
- 3.516852842
- Or divide by
- 0.2843451361
- 1 TR in W
- 3,516.852842
- 1 kW in W
- 1,000
| 75 TR in every power unit | Value |
|---|---|
| Watt (W) | 263,763.9632 |
| Kilowatt (kW) | 263.7639632 |
| Megawatt (MW) | 0.2637639632 |
| Mechanical horsepower (hp) | 353.713301 |
| Metric horsepower (PS) | 358.6191862 |
| Btu per hour (Btu/h) | 900,000 |
| Ton of refrigeration (TR) | 75 |
Formula: result = value × (1 TR in W ÷ 1 kW in W)
Your numbers: 75 × (3,516.852842 ÷ 1,000) = 75 × 3.516852842 = 263.7639632 kW
A ton of refrigeration is 12,000 Btu per hour.
How to convert tons of refrigeration to kilowatts
Tons of Refrigeration to Kilowatts: 1 TR = 3.516852842 kW.
Chiller and air conditioner data sheets often list capacity in tons of refrigeration, while European suppliers, utility engineers and many electrical drawings work in kilowatts. A buyer comparing two quotes, a designer sizing cooling for a server room, or a student solving a thermodynamics problem all need the same conversion. Both numbers describe thermal power, so they compare directly. One ton of refrigeration equals 3.5169 kW of heat removal, a figure that follows from 12,000 Btu per hour.
In your head, use three and a half. That runs low by roughly 0.48 percent, small enough for a first estimate. A 5 TR split system is close to 17.6 kW of cooling, exactly 17.58 kW, and a 15 TR rooftop unit gives 52.75 kW. To go back, divide kilowatts by 3.5 and add a hair. For the reverse direction, one kilowatt of cooling is 0.2843 tons, which is handy for small loads. Rounding the result up gives a small margin on a quote.
The common error is mixing cooling output with electrical input. A 15 TR machine that removes 52.75 kW of heat does not draw 52.75 kW from the grid, since the electrical draw depends on efficiency and is usually well below that. Rounded catalog figures such as 3.5 kW per ton also differ slightly from the exact factor. Keep at least three decimals when the load calculation feeds a purchase decision. The same caution applies to coil, pump and fan loads in a plant, which each add their own draw.
Tons of Refrigeration to Kilowatts: multiply by 3.516852842.
Kilowatts to Tons of Refrigeration: divide by 3.516852842.
Tons of Refrigeration to Kilowatts examples
| TR | Step | kW |
|---|---|---|
| 75 TR | × 3.516852842 | 263.7639632 kW |
| 750.5 TR | × 3.516852842 | 2,639.398058 kW |
| 300 TR | × 3.516852842 | 1,055.055853 kW |
Tons of Refrigeration to Kilowatts table
| TR | kW |
|---|---|
| 20 TR | 70.33705684 kW |
| 24 TR | 84.40446821 kW |
| 25 TR | 87.92132105 kW |
| 40 TR | 140.6741137 kW |
| 45 TR | 158.2583779 kW |
| 50 TR | 175.8426421 kW |
| 120 TR | 422.022341 kW |
| 125 TR | 439.6066053 kW |
| 200 TR | 703.3705684 kW |
| 350 TR | 1,230.898495 kW |
| 500 TR | 1,758.426421 kW |
| 900 TR | 3,165.167558 kW |
| 1,500 TR | 5,275.279263 kW |
| 10,000 TR | 35,168.52842 kW |
Kilowatts to Tons of Refrigeration
| kW | TR |
|---|---|
| 1.5 kW | 0.4265177041 TR |
| 120 kW | 34.12141633 TR |
| 125 kW | 35.54314201 TR |
| 150 kW | 42.65177041 TR |
| 200 kW | 56.86902722 TR |
| 250 kW | 71.08628402 TR |
| 2,500 kW | 710.8628402 TR |
| 5,000 kW | 1,421.72568 TR |
Questions
Kilowatts in one ton of refrigeration?
3.516852842 kW.
TR to kW, the factor?
3.516852842 kW per TR.
Is TR to kW exact?
Exact by definition, shown to 10 digits.
About the data: Factors follow NIST SP 811 and Handbook 44 definitions where they exist. Data units follow IEC 80000-13, with a kilobyte of 1000 bytes and a kibibyte of 1024 bytes. Updated .