List what you want to power. The tool adds up the watts, finds the moment of highest demand and tells you which inverter rating to buy, plus how many amps it pulls from a 12, 24 or 48 volt battery.

  • Free
  • No sign-up
  • Runs in your browser

By Maaz Zindani · Updated

Appliance 1
Appliance 2
Appliance 3
Appliance 4

The names and watts are examples: type your own appliances. Starting watts matter for motors such as a fridge or a pump. Leave the box empty if the appliance has no start-up jump.

Result

600 W invertercontinuous rating, rounded up to the next 100 W · it should also survive a 1,000 W surge

  • 450 W running
  • 750 W at the peak start
  • 25% margin added
ApplianceRuns onStart-up, each
Fridge150450
Ceiling fan × 214070
LED bulb × 66010
TV100100
Total450 W750 W
Current drawn from the battery
BatteryRunningFull size
12 V41.7 A52.1 A
24 V20.8 A26.0 A
48 V10.4 A13.0 A
Running total
450 W
Biggest start-up jump
Fridge: 300 W extra
Peak
450 + 300 = 750 W
Continuous with margin
450 × 1.25 = 563 W
Surge with margin
750 × 1.25 = 938 W

Working: the running watts of every appliance are added. The start-up jump is its starting watts minus its running watts, and only the largest jump is added to the total. Battery amps = inverter watts ÷ (battery volts × 90% efficiency).

Every watt figure here is what you typed. Read the real numbers on each appliance label or manual. Where a label shows amps and volts, multiply them. Ask an electrician before you wire a house.

How to use the Inverter Size Calculator

  1. Fill in a Safety margin and the Inverter efficiency, or keep the example values.
  2. For each appliance, type its Running watts and How many you have. Name it if you like.
  3. For a motor, type its Starting watts as well. Leave the box empty for a lamp or a phone charger.
  4. Press Add another appliance for each extra one, then read the inverter size and the battery amps under Result.

What size inverter do I need?

Add up the running watts of everything that can be on at the same time, then add a margin on top. With the example list on this page the running total is 450 W. A 25% margin brings that to 562.5 W, so the answer is a 600 W inverter once you round up to the next hundred.

The margin is there because labels are rounded, appliances age and an inverter that runs flat out all day gets hot. Pick a margin you are comfortable with. A small one suits a plan where you control what is switched on, and a larger one suits a family that plugs in whatever it likes.

The inverter should be able to carry the total for as long as the lights are on. That is its continuous rating. A second number, the surge rating, tells you how much it can give for a second or two. Both ratings are on the spec sheet of every model, so compare them with the two figures this page gives.

What are starting watts and surge watts?

Starting watts, also called surge or peak watts, are the extra power a motor grabs for a moment when it begins to turn. A fridge compressor, a water pump or a power tool can ask for several times its normal draw for a split second, then settle down. Lamps, TVs and chargers have no such jump.

The calculator takes the starting watts you type and subtracts the running watts to find the jump. In the example, the fridge runs on 150 W and starts at 450 W, so its jump is 300 W. The peak is the running total plus the largest single jump: 450 + 300 = 750 W. Only the largest jump is added because it is unlikely that two motors begin in exactly the same instant. If yours might, type the starting watts of both and use a bigger margin.

Where do the starting watts come from? Read the label or the manual of the appliance. If neither gives a figure, treat the number in the box as a guess and say so to yourself: a guess is fine for a rough plan, and a measured figure is better before you spend money.

The example list at different margins
MarginContinuous wattsRounded upSurge watts
0%450.0500 W750.0
10%495.0500 W825.0
25%562.5600 W937.5
50%675.0700 W1,125.0

How many amps does an inverter draw from the battery?

Divide the watts by the battery voltage, and allow for the energy the inverter itself wastes: amps = watts ÷ (volts × efficiency). At 90% efficiency the running load of 450 W pulls 41.7 A from a 12 V battery, 20.8 A from 24 V and 10.4 A from 48 V. The efficiency you type is an example. Look up the figure for your own model.

A higher battery voltage means fewer amps for the same power, which lets you use thinner and cheaper cables. That is why bigger systems tend to use 24 or 48 volts. The second table in the result also shows the current at the full inverter size, which is the number to use when you choose fuses and cable. Cable and fuse sizing has safety rules of its own, so ask a qualified electrician.

What should I check before I buy an inverter?

Check that the continuous rating is at least the figure in the big answer, and that the surge rating is at least the surge figure in the facts. Check that the battery voltage on the box matches your battery bank. Check the waveform too: motors and some electronics like a pure sine wave inverter better than a modified one.

If you also want to know how long your batteries will last, use the solar battery size calculator. If a petrol or diesel set is on your mind, the generator size calculator uses the same list. To price the energy your appliances use each month, try the electricity cost calculator.

Use it with

Questions

What size inverter do I need for my house?

Add the running watts of everything that may be on together, add a margin and round up. The example list of 450 W with a 25% margin needs 562.5 W, so a 600 W inverter.

How much margin should I add?

It is your choice. The page starts at 25%. A margin of 0% leaves no room, and a larger one such as 50% gives more spare power and costs more.

Do I add the starting watts of every appliance?

No. Add the running watts of all of them, then add only the largest jump (starting watts minus running watts). Two motors seldom start at the same instant.

How many amps does a 1000 W inverter pull from a 12 V battery?

At 90% efficiency: 1000 ÷ (12 × 0.9) = 92.6 A. At 24 V it is 46.3 A and at 48 V it is 23.1 A.

What is the difference between continuous and surge rating?

Continuous is what the inverter can supply all the time. Surge is a short burst, a second or two, to start motors. Check both against the figures on this page.

Can I use this for a solar system?

Yes for the inverter. The battery bank is a separate question: the solar battery size calculator turns your daily watt-hours into amp-hours and a number of batteries.

The tool's results are computed in your browser by the code on this page; the explanations are checked against the tool's own output.