Write down what the generator must power. You get the smallest rating that covers the steady load and the hardest start-up, in watts, kilowatts and kVA.

  • Free
  • No sign-up
  • Runs in your browser

By Maaz Zindani · Updated

Appliance 1
Appliance 2
Appliance 3
Appliance 4

The loads are examples: type your own. Add starting watts for anything with a motor or compressor. Leave it empty for lamps and electronics.

Result

1.5 kW generator1,500 W running · at least 3,200 W starting · about 1.8 kVA

  • 1,180 W to run
  • 2,630 W at the hardest start
  • power factor 0.8
LoadRunning WStart jump W
Fridge200600
Water pump7501,450
LED lights × 8800
TV and router1500
Total1,1801,450 (biggest)
Running rating needed
1,180 × 1.2 = 1,416 W
Starting rating needed
2,630 × 1.2 = 3,156 W
In kilowatts
1.42 kW running, 3.16 kW starting
In kVA
1,416 ÷ 0.8 = 1.77 kVA running, 3.94 kVA starting
Hardest start
Water pump: 1,450 W above its running watts

Working: the running watts of all loads that may be on together are added. The hardest start adds only the biggest jump, which is starting watts minus running watts of one unit. Both totals get the margin. kVA is watts divided by the power factor.

Watts, starting watts and the power factor are your own entries. Read them from each label or manual, and from the generator's data plate. Check the final choice with a qualified electrician, mainly if it connects to a house.

How to use the Generator Size Calculator

  1. Set the Safety margin and the Power factor, or keep the example values.
  2. For each load, type its Running watts and How many you have.
  3. For anything with a motor or compressor, type the Starting watts as well.
  4. Press Add another load as needed, then read the generator size under Result.

What size generator do I need?

You need a generator whose running rating is above the total of everything you will run together, and whose starting rating is above the hardest start-up. For the example loads the running total is 1,180 W. Adding the 20% margin gives 1,416 W, so a 1.5 kW generator is the smallest that fits.

Switch on only what is needed during an outage. A shorter list often means a much smaller, quieter and cheaper machine. Take the fridge, a few lights and the router, and leave the oven off.

Running watts and starting watts are the two ratings printed on most portable generators. Use the first for the steady load and the second for the short burst when a motor starts.

How do running and starting watts differ?

Running watts are the steady draw. Starting watts are the short peak that a motor, pump or compressor asks for when it begins to turn, typically a second or two. In the example, the water pump runs on 750 W and starts at 2,200 W, so it adds 1,450 W on top of the running total. The peak is 1,180 + 1,450 = 2,630 W.

Only the largest jump is added. The calculation assumes that motors start one after another, not all in the same instant. If you can arrange for that, for instance by switching things on one at a time, the smaller figure is right. If an automatic switch could start two motors together, type their starting watts and raise the margin.

The example list with different margins
MarginRunning ratingStarting ratingkVA running
0%1,200 W2,700 W1.48
10%1,300 W2,900 W1.62
20%1,500 W3,200 W1.77
30%1,600 W3,500 W1.92

How do I convert watts to kVA or kW?

A kilowatt is 1,000 watts, so 1,500 W is 1.5 kW. A generator may be rated in kVA, which is the apparent power. Real power in watts equals kVA × power factor, so kVA = watts ÷ power factor. With a power factor of 0.8, the running need of 1,416 W is 1.77 kVA.

The power factor of 0.8 in the box is an example. Look at the data plate of the generator you are considering and use its figure. If the plate shows kVA and a power factor, multiply them to get the watts you can really draw.

What else should I check before choosing a generator?

Check that the generator can run for as long as you need on the fuel you can store, and that it has outlets and breakers of the right type. Never run one inside a building or close to a window, because the exhaust is dangerous. A house connection needs a proper transfer switch fitted by a qualified person.

To compare with batteries, the inverter size calculator takes the same kind of list and gives an inverter rating and battery amps. The electricity cost calculator shows what the same loads cost on the grid.

Use it with

Questions

How do I calculate what size generator I need?

Add the running watts of all the loads that run together, add a margin, and check that the starting rating also covers the hardest start-up. The example needs 1,416 W running and 3,156 W starting.

How many watts do I add for starting motors?

Add only the biggest jump: starting watts minus running watts of the one unit with the largest surge. In the example the pump adds 1,450 W.

How do I convert watts to kVA?

Divide the watts by the power factor. 1,416 W at a power factor of 0.8 is 1.77 kVA.

How much margin should I leave?

The choice is yours. The page starts at 20%, which gives some room for aging and for label figures that are low. A larger margin gives more spare power and a bigger machine.

Is a 5 kW generator enough for a house?

It depends on what you switch on together. List the loads here, and compare the running and starting totals with the generator ratings. Nothing about a house is fixed in advance.

Can I add the surge watts of every appliance?

You can, as a safe extreme: type a larger margin or list the starting watts. The standard method adds only the largest jump, since motors seldom start at the same moment.

The tool's results are computed in your browser by the code on this page; the explanations are checked against the tool's own output.